<<= Back Next =>>
You Are On Multi Choice Question Bank SET 767

38351. Who among the following participated in Dandi March of 1930 with Mahatma Gandhi?





38352. __________ is the static characteristics of an instrument,





38353. Phase lag of the frequency response of a second order system to a sinusoidal forcing function





38354. Dead zone in an instrument must be less than __________ percent of the scale.





38355. Emission spectroscopy is used for





38356. Gas analysis is commonly done using the





38357. The open loop transfer function of a control system is . This represents





38358. Thermal conductivity measurement is used for the determination of





38359. Presence of a small amount of water in the organic systems can be determined by the __________ method.





38360. The transfer function of a pure dead time system with dead time τd is





38361. Thermal conductivity cell is the primary element of a/an __________ analyser.





38362. Zirconia probe is used for the measurement of





38363. The root locus method, a pole of a transfer function G(s) is the value of s for which G(s) approaches





38364. __________ type of element is normally not used in the bimetallic thermometers.





38365. Suppose that the gain, time constant and dead time of a process with the following transfer function:Gc(s) = 10 exp( - 0.1s)/(0.5s + 1) are known with a possible error of ± 20% of their values. The largest permissible gain Kc of a proportional controller needs to be calculated below taking the values of process gain, time constant and dead time as





38366. Process degree of freedom indicates __________ number of controllers to be used.





38367. Characteristic equation is the denominator of __________ loop transfer function.





38368. Operating range of a temperature measuring instrument is 800 to 1600°C. It could be a/an __________ pyrometer.





38369. Polarograph is meant for the analysis of





38370. Which of the following fluid flow measuring devices can measure the largest flow rate ?





38371. Flow rate of sludge is not measured by a/an





38372. In a shell and tube heat exchanger, the inlet temperature of heating/cooling fluid is the __________ variable.





38373. Which of following error integral is considered as the best criterion in controller settings ?


38374. Polarisation of light forms the working principle of a





38375. A bimetallic thermometer as compared to industrial mercury in glass thermometer has almost the same





<<= Back Next =>>
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use
DMCA.com Protection Status Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions