<<= Back Next =>>
You Are On Multi Choice Question Bank SET 1501

75051. The accuracy of measurement using CRO is about





75052. The channel required for FM telemetry is





75053. Assertion (A): Absolute instruments are used in standard laboratories.Reason (R): Absolute instruments do not require calibration.





75054. Assertion (A): A 3 phase wattmeter consists of two wattmeters mounted in one case.Reason (R): Power measurement in a 3 phase circuit can be conveniently done by two wattmeter method.





75055. A digital voltmeter can count from 0 to 9999. If full scale reading is 9.999 V, the resolution of full scale reading is





75056. The most serious problems in ac bridge measurement is





75057. Assertion (A): An electrostatic voltmeter is free from hysteresis and eddy current errors.Reason (R): An electrostatic voltmeter has a number of fixed and moving vanes in parallel.





75058. The pointer of an indicating instrument should be





75059. The resistance of resistance strain gauge is about





75060. Which bridge can be used to measure frequency?





75061. The time base generator in a CRO gives an output which is





75062. An average responding rectifier type electronic voltmeter has its scale calibrated in terms of rms value of sine wave. If 100 V peak value square wave is fed to this voltmeter, the reading will be





75063. In low power factor wattmeter, the compensating coil is connected





75064. A permanent magnet moving coil measures





75065. A CT is used to feed current coils of wattmeter, energy meter, power factor meter and an ammeter. Then





75066. In measurements using strain gauge, the dummy strain gauge is used to





75067. In an ac single phase energy meter, the potential coil is put on





75068. The chemical effect of current is used in





75069. In a single phase power factor meter the phase difference between currents in the two pressure coils is





75070. In an ac coordinate potentiometer, the currents inphase and quadrature potentiometer are adjusted to be





75071. Both X and Y plates of a CRO are excited by ac signals. The display is an ellipse which makes one rotation in 5 seconds. This means that





75072. In order to achieve accuracy, the slide wire of a potentiometer should be





75073. In measuring resistance using voltmeter and ammeter, the resistances of voltmeter and ammeter also affect the accuracy of measurement.



75074. The difference between measured value and true value is called





75075. In air friction damping





75076. In indicating instruments the controlling torque is provided by a spring.



75077. For measuring a very high resistance we should use




75078. Assertion (A): Damping in a vibration galvanometer is small.Reason (R): Vibration galvanometer is a PMMC instrument.





75079. In a platinum RTD, the change in resistance for a temperature rise of 50° C is about





75080. The gauge factor of a semiconductor strain gauge is about





75081. Which of the following instruments is used almost exclusively to measure radio frequency currents?





75082. The coil of a DArsonval galvanometer has N turns. If flux density is B, current is I and area of coil is A, the deflecting torque is





75083. Consider the following statements regarding electromagnetic flowmeter AC excitation is used to avoid polarisation of fluid.The meter calibration is changed as viscosity of fluid changes.Stainless steel pipes can be used for measuring the flow of liquid of high conductivity. Of the above statements





75084. In a CRO, the time base signal is applied to





75085. Schering bridge operates at a high voltage of about 10 kV.



75086. Which of these instrument does not have a control spring?





75087. In Weston frequency meter, the magnetic axes of the two fixed coils are





75088. A 4-ohm resistor is connected across a 12 V battery.The current flowing will be





75089. Pirani gauge is used to measure





75090. Assertion (A): CRT is the most important component of a CRO.Reason (R): When an electron beam strikes the screen of CRT, a spot of light is produced.





75091. A capacitance transducer has two plates each of area 5 mm2. The coil gap is 2 mm. Displacement sensitivity due to change in gap length is





75092. Four capacitors are in parallel. Their values are 36.3 μF, 3.85 μF, 34.002 μF and 850 μF with an uncertainty of digit in the last place. The total capacitance in significant figures is





75093. In figure, C0 is distributed capacitance and C is tuning capacitor. If C = C1 for fundamental frequency and C = C2 for second harmonic, then C0 =


75094. If M is mutual inductance between fixed and moving coils and θ is deflection of dynamometer instrument, then



75095. The switch board instruments





75096. Radiation pyrometer is used to measure temperature in the range of





75097. The electromagnets of an induction wattmeter





75098. In a vibrating reed frequency meter the natural frequency of two adjacent reeds have a difference of





75099. Assertion (A): CRO can be used to study waveshape accurately.Reason (R): Input impedance of a CRO is very high.





75100. LVDT is used to measure





<<= Back Next =>>
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use
DMCA.com Protection Status Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions