Toggle navigation
Home
Article Category
Question Papers
General Knowlege
Popular Pages
Multiple Choice Question in
Multiple Choice Question in 049
Multiple Choice Question in 2016
Multiple Choice Question in -current-affairs-2016
Multiple Choice Question in TRADES-INSTRUCTOR---GR-II---SMITHY---TECHNICAL-EDUCATION
Question Answer in ASSISTANT-PROFESSOR---COMPUTER-SCIENCE-AND-ENGINEERING---TECHNICAL-EDUCATION
Multiple Choice Question in ASSISTANT-PROFESSOR---COMPUTER-SCIENCE-AND-ENGINEERING---TECHNICAL-EDUCATION
Multiple Choice Question in english
Multiple Choice Question in abbreviations-abbreviations-m
Multiple Choice Question in SSC CHSL 7 March 2018 Morning Shift
Multiple Choice Question in 072/2016
Question Answer Bank
Multiple Choice Question Bank
Question Answer Category
Multiple Choice Question Category
Home
->
Multiple Choice Questions
1. The transfer function for a PID controller is (where, τ i is the integral (reset) time and τD is the derivative time.)
(A): Kc(1 + τis + τD ). s
Previous Question
Show Answer
Next Question
Add Tags
Report Error
Show Marks
Write Comment
Type in
(Press Ctrl+g to toggle between English and the chosen language)
Post reply
Comments
Tags
Show Similar Question And Answers
QA->The DMA transfer technique where the transfer of one word data at a time:....
QA->What command is used to reset a MODEM when using the AT Command Set?....
QA->Malayalam film actor and still-photographer who was an integral part in projects of ace directors such as Adoor Gopalakrishnan, Aravindan and John Abraham, passed away on December 25, 2014?....
QA->French footballer, integral to the French national team of the 1950s who played for Real Madrid between 1956 and 1959, passed away on March 3, 2017?....
QA->Integral Coach Factory is located in ?....
MCQ->The transfer function for a PID controller is (where, τ i is the integral (reset) time and τD is the derivative time.)....
MCQ->Assertion (A): When a PID controller is added to a system, the peak overshoot to step input cannot be determined easily.Reason (R): Use of PID controller introduces a zero in the forward path.....
MCQ->Assertion (A): When the performance of a stable second order system is improved by a PID controller, the system may become unstable.Reason (R): PID controller increases the order of the system to 3.....
MCQ->In a closed loop system, the process to be controlled is an integrating process with transfer function l/2s. The controller proposed to be used in an integral controller with transfer function 1/T1s. When a step change in set point is applied to such a closed loop system, the controlled variable will exhibit....
MCQ->An ideal PID controller has the transfer function . The frequency at which the magnitude ratio of the controller is 1, is....
×
×
Type The Issue
×
Your Marks
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use
Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...
Privacy
|
Terms And Conditions