<<= Back Next =>>
You Are On Multi Choice Question Bank SET 1496

74801. Assertion (A): Shunt of an ammeter has a low resistance.Reason (R): Shunt may be connected in series or in parallel with ammeter.





74802. The scale of hot wire instrument is linear.



74803. The D'Arsonval- movement can be converted into audio frequency ac ammeter by adding a





74804. The resistance of a 125 Ω strain gauge changes by 1 ohm for 4000 micro strain. The gauge factor is





74805. Electrostatic voltmeter is suitable only for low voltages.



74806. An accelerometer has a seismic mass of 0.05 kg and spring constant of 3 x 105 N/m. If maximum displacement of mass is ± 1 mm, the maximum acceleration which can be measured is





74807. If an inductance L is connected in one arm of bridge and resistance R1, R2, R3 in other three arms





74808. A moving iron voltmeter reads 250 V when connected to 250 V dc. If connected to 250 V 50 Hz, the voltmeter reading is likely to be





74809. A single element strain gauge bridge has two fixed resistances R1 and R1 of 120 Ω each and a variable resistance which gives full deflection at 120 Ω for zero strain and 120.6 Ω for straine e. If gauge factor is 2, strain e is





74810. LVDT is a





74811. A 0-200 V voltmeter has an accuracy of 0.75% of full scale reading. If voltage measured is 100 V, the error is





74812. In Schering bridge, the potential of detector above earth potential is about





74813. The dimensions of EMF are





74814. Which of the following instruments has non-linear scale? Moving coil instrumentMoving iron instrumentElectrostatic instrumentRectifier instrument Select the answer as per following codes





74815. The power input and output in a device are 3650 W and 3385 W with each reading in doubt by ± 10 W. The percentage uncertainty in losses is





74816. A meter coil has a resistance of 100 Ω and a full scale deflection current of 10 mA. To convert it into a voltmeter of 0-200 V range, the series resistance should be





74817. Which of these has a magnetic brake?





74818. Two numbers are 131 ± 5 and 629 ± 3. The sum of the numbers with range of doubt is





74819. Assertion (A): Schering bridge is a low voltage bridge.Reason (R): Schering bridge is very commonly used for measurement of capacitance.





74820. Assertion (A): Wien bridge can be used for measuring frequency.Reason (R): A frequency meter for 50 Hz system has a frequency range of 40 to 60 Hz.





74821. Which of these has poor overload capacity?





74822. In 3 phase power measurement by two wattmeter method, both wattmeters had equal reading. The power factor of load is





74823. Which instrument is based on induction principle?





74824. Magnetic field intensity has the dimensions





74825. In figure, the position of voltmeter and ammeter are exchanged. It may result in damage to





74826. The volt ratio box is basically a





74827. A sinusoidal ac voltage of amplitude 100 V is applied to a rectifying device which offers 10 Ω resistance in forward direction and infinite resistance in backward direction. A moving coil ammeter is also connected in the circuit. The reading of ammeter will be





74828. A variable reluctance tachometer has 180 teeth on rotor. The speed of shaft on which it is mounted in 1200 rpm. The frequency of output pulses is





74829. In the wheatstone bridge in figure, each resistance is increased by 0.05%. The value of v0 will be





74830. Consider the following operation in respect of Wheatstone bridge (Kb, denotes battery key, Kg denotes galvanometer key) open Kbclose Kgclose Kbopen Kg The correct sequence of operations is





74831. Two voltmeters 0-250 V each having resistances of 5 kΩ and 10 kΩ respectively and are connected in series. To ensure that neither of them goes beyond scale the total voltage which can be applied should be less than





74832. A 24 mm long conductor has a resistance of 128 Ω. The change in resistance is 13.3 Ω and change in length is 1.6 mm under tension. The gauge factor is





74833. Measuring of unknown voltage with a dc potentiometer loses its advantage of open circuit measurement when





74834. In a digital measuring device the input electrical signal is in the frequency range of dc to ac (50) Hz. It must be sampled at a rate of





74835. A meter has a square law scale. For 2 A current the deflection in 90°. For a deflection of 45°, the current is





74836. Consider the following Statements regarding resistance strain gauge The gauge factor is in the range of 2 to 5.The resistance changes due to change in specific resistance with strain.The resistance increases with increase in temperature. Of the above statements, which are correct?





74837. PCM employing 4 bit code is used to send data having frequency range from 0 to 2 kHz. The minimum required bandwidth of carrier channel is





74838. A sinusoidal ac voltage of amplitude 100 V is applied to a rectifying device which offers 10 Ω resistance in forward direction and infinite resistance in reverse direction. The reading on hot wire ammeter will be





74839. When a capacitor is connected to the terminals of an ohmmeter, the pointer indicated a low resistance initially and finally come to infinity position. This shows that capacitor is





74840. If eddy current damping is to be used, the disc of instrument should be





74841. The scale of moving iron instrument is linear.



74842. With a variable reluctance tachometer having 60 rotor teeth the count reads 3600 counts per minute. The speed in RPM is





74843. When measuring phase angle between two waves using a CRO, the time base generator is connected to





74844. It is required that a strain gauge has gauge factor of 100. The proper strain gauge is





74845. A meter having 0-1000 μA range and 1000 Ω resistance is required to be changed to 0-100 mA meter. The value of shunt resistance is about





74846. An induction wattmeter can be used for





74847. In the balanced bridge shown in figure. X should be





74848. If the current in a capacitor leads the voltage by 80°, the loss angle of capacitor is





74849. In an induction wattmeter, the shading bands are made of non conducting material.



74850. The current in a circuit is measured using a 150 : 1 CT If the ammeter reads 0.6 A, the circuit current is





<<= Back Next =>>
Terms And Service:We do not guarantee the accuracy of available data ..We Provide Information On Public Data.. Please consult an expert before using this data for commercial or personal use
DMCA.com Protection Status Powered By:Omega Web Solutions
© 2002-2017 Omega Education PVT LTD...Privacy | Terms And Conditions